Kamke D | Scherbaum B | Brasu T | Kutz G
Energy Consumption of Four Granulation Techniques in Lab-Scale / A Case Study · Kamke D, Scherbaum B, Brasu T, Kutz G · Technische Hochschule Ostwestfalen-Lippe, Detmold und
energy consumption wet granulation melt granulation fluid bed granulator high-shear granulator Against the background of an increasing environmental awareness and a tendency to sustainable and lean manufacturing processes there is a strong need of pharmaceutical manufacturers to establish more sustainable production processes to save time as well as money and to reduce waste and emissions. For an ecological optimization of a manufacturing process, there are various opportunities like elimination of energy intensive manufacturing steps and reduction of waste/emissions. Process steps with high-energy consumption can be identified by monitoring their power consumption. Such process steps can be reduced, shortened or completely ...